Larger Distributed Energy Resources (DER) generation plants, such as wind, solar or photovoltaic (PV) plants, are generally connected to the power network at the medium voltage (MV) level.

The challenge is to keep the voltage and frequency stable with a higher degree of DER plants and generate the necessary power to cover the gap for the reduced amount of large and stable generation plants.

To cope with that change, IEC released a new standard, IEC 60255-181:2019, with the focus on frequency protection, specifying relay performances and test methodologies of frequency protection schemes, including Rate of Change of Frequency (ROCOF), which Megger complies with in its solutions.

blue arrow

Customers testimonials
In PV plants and substations

Protection testing
In PV plants with the SVERKER900

Protection testing
In Wind Farms with the SVERKER900

Protection in DER plants

The protection circuits and functions are very similar to regular substations at MV level. Since it is in an MV environment, the protection functions in PV farms are basic. Typically they are under/over voltage, under/over frequency, ROCOF, vector shift, and unbalance protection functions.

white arrow

Frequency protection functions

The new IEC standard affects how tests are performed on frequency protection functions, including ROCOF. For example, the standard includes a standardised formula for frequency change with smooth frequency change which better reflects the reality, and specifies test frequencies and report structures.

Self-Powered Relays (SPRs)

SPRs are frequently used since they harvest their energy from the network and don't need a DC supply to operate, keeping the costs down. Even though they normally have basic protection functions, they can be a challenge to test for modern relay testers.

Multi-functional solution for relay and substation testing in
grid-connected plants.
SVERKER900

Time-saving solution for relay protection testing in grid-connected plants.
SMRT and FREJA

white arrow

Resources

Check out these resources to get the most out of your relay protection testing
in grid-connected distributed energy resource plants.
Videos, interviews and podcasts
Latest technical information
Webinars
A little touch-up animation for the paragraph that reveals on expand

To make things a little livelier, I added a nice little touch up to the paragraph by creating a slide in animation from below. So, instead of being still upon expand, it will slide in from below nicely.

Additional interaction to create focus/highlight on specific item (Optional)

I added a focus/highlight effect to make the item that's on hover stands out from the rest. This helps the user to focus on the item that they are reading.

This is definitely optional. You can remove this animation from the interaction setting. It's a separate interaction from the expand/collapse.

cable life expectancy megger

Webinars

test for general system megger

IEC 61850 Solutions

test for new installation commissioning megger

Latest Technical Content

test for new installation commissioning megger

Videos

cable life expectancy megger

Webinars

test for general system megger

IEC 61850 Solutions

test for new installation commissioning megger

Latest Technical Content

test for new installation commissioning megger

Videos

Contact Us

Use this form to get in touch - We love to hear from our users

Leave a phone number if you want us to phone you back.

X

Talk to an expert